Skip to content
Vectis Controls

Sizing a Quarter-Turn Actuator to a Valve

Matching actuator output curves to valve torque points, with differential pressure correction and safety factors.

Updated

  • sizing
  • torque
  • safety factor
  • BTO

Actuator sizing is a curve-matching exercise, not a single number. A quarter-turn valve manufacturer publishes torques at several points in its stroke, and the actuator must exceed each one (with a safety factor) at the minimum supply pressure.

Valve torque points

  • BTO -> Break To Open (usually the highest demand)
  • RTO -> Run To Open (mid-stroke)
  • ETO -> End To Open
  • BTC -> Break To Close
  • RTC -> Run To Close
  • ETC -> End To Close (seating torque)

Correcting for differential pressure

Manufacturer torques are usually quoted at full differential pressure. In this case, they can be used without correction. In some circumstances, the torques can be given at reference ΔP. Where operational ΔP is different, many manufacturers allow the pressure-dependent part of the torque to be scaled. Never scale below the published zero-ΔP (seat/packing) torque, or above the operating pressure of the valve. Most clients require the actuator to be sized with full ΔP across the valve.

Safety Factors

Torque Safety Factor

Clients usually require a specific safety factor to be applied to the given valve torques. This gives the actuator more power than is necessary to account for:

  • Unit-to-unit manufacturing tolerances.
  • Degradation over time (including corrosion).
  • Unexpected operation conditions.
  • Excess friction in any part of the motive chain.
  • Build up of debris.

The safety factor for each of the 6 torque positions should be calculated.

SF=TactuatorTvalveSF = \frac{T_{actuator}}{T_{valve}}

The safety factor should be calculated for each of the 6 given torque positions. The lowest of these 6 calculated safety factors is the performance limit of the assembly.

Typical safety factors: 1.5 for clean on/off duty, 2.0 or higher for infrequent operation, dirty or sour service.

MAST Safety Factor

The MAST Safety factor is required to ensure the actuator cannot physically damage the valve in the case of an obstruction, a stuck valve, or when a valve needs to be torque seated.

SFMAST=TMASTTactuator maxSF_{MAST} = \frac{ T_{MAST}}{T_{actuator\space max}}

Where: SFMASTSF_{MAST} = The resulting assemblies MAST Safety Factor. TMASTT_{MAST} = The MAST of the valve, provided by the manufacturer. Tactuator maxT_{actuator\space max} = The highest torque produced by the actuator.

Matching the curves

Compare the actuator output at the start, run and end of stroke against the corresponding required valve torque.

Actuator Sized on Valve

Torque values from manufacturer data.

The shape of the output depends on mechanism (see Scotch Yoke vs Rack & Pinion) and for spring-return units the spring stroke is checked separately, see Reading Spring-Return Torque Curves.

The MAST and MAWP Trap

This article has so far covered calculating the MAST safety factor at the given minimum operating pressure of the actuator. There is another situation that should be calculated and allowed for though. The Maximum Allowable Working Pressure.

Usually in the context of an actuator, this represents the maximum pressure the actuator is designed to run at. Depending on your controls, a failure could allow full supply pressure to reach the actuator. What is the torque of the actuator then?

When calculating the MAST safety factor, the maximum torque of the actuator should be assessed at an operation pressure it could see. E.g:

  • If an air filter regulator fails, what is the maximum supply pressure?
  • If an air regulator fail, but a pressure relief valve is present, what is the setpoint of the pressure relief valve?
  • Is there an air filter regulator or pressure relief valve present? if not, what is the maxumum supply pressure?

The highest supply pressure should be derrived from the controls implemented. Once this operating pressure has been defined, the actuator torque can be found for that specific operating pressure. This value should be used in the MAST safety factor calculation.

Connected articles